//\//////////////////////////////////////////////////////////////////////////////////
//\  overLIB 3.50  --  This notice must remain untouched at all times.
//\  Copyright Erik Bosrup 1998-2001. All rights reserved.
//\
//\  By Erik Bosrup (erik@bosrup.com).  Last modified 2001-08-28.
//\  Portions by Dan Steinman (dansteinman.com). Additions by other people are
//\  listed on the overLIB homepage.
//\
//\  Get the latest version at http://www.bosrup.com/web/overlib/
//\
//\  This script is published under an open source license. Please read the license
//\  agreement online at: http://www.bosrup.com/web/overlib/license.html
//\  If you have questions regarding the license please contact erik@bosrup.com.
//\
//\  This script library was originally created for personal use. By request it has
//\  later been made public. This is free software. Do not sell this as your own
//\  work, or remove this copyright notice. For full details on copying or changing
//\  this script please read the license agreement at the link above.
//\
//\  Please give credit on sites that use overLIB and submit changes of the script
//\  so other people can use them as well. This script is free to use, don't abuse.
//\//////////////////////////////////////////////////////////////////////////////////
//\mini

//document.domain="yaskawa.com"

////////////////////////////////////////////////////////////////////////////////////
// CONSTANTS
// Don't touch these. :)
////////////////////////////////////////////////////////////////////////////////////
var INARRAY		=	1;
var CAPARRAY		=	2;
var STICKY		=	3;
var BACKGROUND		=	4;
var NOCLOSE		=	5;
var CAPTION		=	6;
var LEFT		=	7;
var RIGHT		=	8;
var CENTER		=	9;
var OFFSETX		=	10;
var OFFSETY		=	11;
var FGCOLOR		=	12;
var BGCOLOR		=	13;
var TEXTCOLOR		=	14;
var CAPCOLOR		=	15;
var CLOSECOLOR		=	16;
var WIDTH		=	17;
var BORDER		=	18;
var STATUS		=	19;
var AUTOSTATUS		=	20;
var AUTOSTATUSCAP	=	21;
var HEIGHT		=	22;
var CLOSETEXT		=	23;
var SNAPX		=	24;
var SNAPY		=	25;
var FIXX		=	26;
var FIXY		=	27;
var FGBACKGROUND	=	28;
var BGBACKGROUND	=	29;
var PADX		=	30; // PADX2 out
var PADY		=	31; // PADY2 out
var FULLHTML		=	34;
var ABOVE		=	35;
var BELOW		=	36;
var CAPICON		=	37;
var TEXTFONT		=	38;
var CAPTIONFONT		=	39;
var CLOSEFONT		=	40;
var TEXTSIZE		=	41;
var CAPTIONSIZE		=	42;
var CLOSESIZE		=	43;
var FRAME		=	44;
var TIMEOUT		=	45;
var FUNCTION		=	46;
var DELAY		=	47;
var HAUTO		=	48;
var VAUTO		=	49;
var CLOSECLICK		=	50;
var CSSOFF		=	51;
var CSSSTYLE		=	52;
var CSSCLASS		=	53;
var FGCLASS		=	54;
var BGCLASS		=	55;
var TEXTFONTCLASS	=	56;
var CAPTIONFONTCLASS	=	57;
var CLOSEFONTCLASS	=	58;
var PADUNIT		=	59;
var HEIGHTUNIT		=	60;
var WIDTHUNIT		=	61;
var TEXTSIZEUNIT	=	62;
var TEXTDECORATION	=	63;
var TEXTSTYLE		=	64;
var TEXTWEIGHT		=	65;
var CAPTIONSIZEUNIT	=	66;
var CAPTIONDECORATION	=	67;
var CAPTIONSTYLE	=	68;
var CAPTIONWEIGHT	=	69;
var CLOSESIZEUNIT	=	70;
var CLOSEDECORATION	=	71;
var CLOSESTYLE		=	72;
var CLOSEWEIGHT		=	73;


////////////////////////////////////////////////////////////////////////////////////
// DEFAULT CONFIGURATION
// You don't have to change anything here if you don't want to. All of this can be
// changed on your html page or through an overLIB call.
////////////////////////////////////////////////////////////////////////////////////

// Main background color (the large area)
// Usually a bright color (white, yellow etc)
if (typeof ol_fgcolor == 'undefined') { var ol_fgcolor = "#CCCCFF";}
	
// Border color and color of caption
// Usually a dark color (black, brown etc)
if (typeof ol_bgcolor == 'undefined') { var ol_bgcolor = "#333399";}
	
// Text color
// Usually a dark color
if (typeof ol_textcolor == 'undefined') { var ol_textcolor = "#000000";}
	
// Color of the caption text
// Usually a bright color
if (typeof ol_capcolor == 'undefined') { var ol_capcolor = "#FFFFFF";}
	
// Color of "Close" when using Sticky
// Usually a semi-bright color
if (typeof ol_closecolor == 'undefined') { var ol_closecolor = "#9999FF";}

// Font face for the main text
if (typeof ol_textfont == 'undefined') { var ol_textfont = "Verdana,Arial,Helvetica";}

// Font face for the caption
if (typeof ol_captionfont == 'undefined') { var ol_captionfont = "Verdana,Arial,Helvetica";}

// Font face for the close text
if (typeof ol_closefont == 'undefined') { var ol_closefont = "Verdana,Arial,Helvetica";}

// Font size for the main text
// When using CSS this will be very small.
if (typeof ol_textsize == 'undefined') { var ol_textsize = "1";}

// Font size for the caption
// When using CSS this will be very small.
if (typeof ol_captionsize == 'undefined') { var ol_captionsize = "1";}

// Font size for the close text
// When using CSS this will be very small.
if (typeof ol_closesize == 'undefined') { var ol_closesize = "1";}

// Width of the popups in pixels
// 100-300 pixels is typical
if (typeof ol_width == 'undefined') { var ol_width = "200";}

// How thick the ol_border should be in pixels
// 1-3 pixels is typical
if (typeof ol_border == 'undefined') { var ol_border = "1";}

// How many pixels to the right/left of the cursor to show the popup
// Values between 3 and 12 are best
if (typeof ol_offsetx == 'undefined') { var ol_offsetx = 10;}
	
// How many pixels to the below the cursor to show the popup
// Values between 3 and 12 are best
if (typeof ol_offsety == 'undefined') { var ol_offsety = 10;}

// Default text for popups
// Should you forget to pass something to overLIB this will be displayed.
if (typeof ol_text == 'undefined') { var ol_text = "Default Text"; }

// Default caption
// You should leave this blank or you will have problems making non caps popups.
if (typeof ol_cap == 'undefined') { var ol_cap = ""; }

// Decides if sticky popups are default.
// 0 for non, 1 for stickies.
if (typeof ol_sticky == 'undefined') { var ol_sticky = 0; }

// Default background image. Better left empty unless you always want one.
if (typeof ol_background == 'undefined') { var ol_background = ""; }

// Text for the closing sticky popups.
// Normal is "Close".
if (typeof ol_close == 'undefined') { var ol_close = "Close"; }

// Default vertical alignment for popups.
// It's best to leave RIGHT here. Other options are LEFT and CENTER.
if (typeof ol_hpos == 'undefined') { var ol_hpos = RIGHT; }

// Default status bar text when a popup is invoked.
if (typeof ol_status == 'undefined') { var ol_status = ""; }

// If the status bar automatically should load either text or caption.
// 0=nothing, 1=text, 2=caption
if (typeof ol_autostatus == 'undefined') { var ol_autostatus = 0; }

// Default height for popup. Often best left alone.
if (typeof ol_height == 'undefined') { var ol_height = -1; }

// Horizontal grid spacing that popups will snap to.
// 0 makes no grid, anything else will cause a snap to that grid spacing.
if (typeof ol_snapx == 'undefined') { var ol_snapx = 0; }

// Vertical grid spacing that popups will snap to.
// 0 makes no grid, andthing else will cause a snap to that grid spacing.
if (typeof ol_snapy == 'undefined') { var ol_snapy = 0; }

// Sets the popups horizontal position to a fixed column.
// Anything above -1 will cause fixed position.
if (typeof ol_fixx == 'undefined') { var ol_fixx = -1; }

// Sets the popups vertical position to a fixed row.
// Anything above -1 will cause fixed position.
if (typeof ol_fixy == 'undefined') { var ol_fixy = -1; }

// Background image for the popups inside.
if (typeof ol_fgbackground == 'undefined') { var ol_fgbackground = ""; }

// Background image for the popups frame.
if (typeof ol_bgbackground == 'undefined') { var ol_bgbackground = ""; }

// How much horizontal left padding text should get by default when BACKGROUND is used.
if (typeof ol_padxl == 'undefined') { var ol_padxl = 1; }

// How much horizontal right padding text should get by default when BACKGROUND is used.
if (typeof ol_padxr == 'undefined') { var ol_padxr = 1; }

// How much vertical top padding text should get by default when BACKGROUND is used.
if (typeof ol_padyt == 'undefined') { var ol_padyt = 1; }

// How much vertical bottom padding text should get by default when BACKGROUND is used.
if (typeof ol_padyb == 'undefined') { var ol_padyb = 1; }

// If the user by default must supply all html for complete popup control.
// Set to 1 to activate, 0 otherwise.
if (typeof ol_fullhtml == 'undefined') { var ol_fullhtml = 0; }

// Default vertical position of the popup. Default should normally be BELOW.
// ABOVE only works when HEIGHT is defined.
if (typeof ol_vpos == 'undefined') { var ol_vpos = BELOW; }

// Default height of popup to use when placing the popup above the cursor.
if (typeof ol_aboveheight == 'undefined') { var ol_aboveheight = 0; }

// Default icon to place next to the popups caption.
if (typeof ol_caption == 'undefined') { var ol_capicon = ""; }

// Default frame. We default to current frame if there is no frame defined.
if (typeof ol_frame == 'undefined') { var ol_frame = self; }

// Default timeout. By default there is no timeout.
if (typeof ol_timeout == 'undefined') { var ol_timeout = 0; }

// Default javascript funktion. By default there is none.
if (typeof ol_function == 'undefined') { var ol_function = Function(); }

// Default timeout. By default there is no timeout.
if (typeof ol_delay == 'undefined') { var ol_delay = 0; }

// If overLIB should decide the horizontal placement.
if (typeof ol_hauto == 'undefined') { var ol_hauto = 0; }

// If overLIB should decide the vertical placement.
if (typeof ol_vauto == 'undefined') { var ol_vauto = 0; }



// If the user has to click to close stickies.
if (typeof ol_closeclick == 'undefined') { var ol_closeclick = 0; }

// This variable determines if you want to use CSS or inline definitions.
// CSSOFF=no CSS    CSSSTYLE=use CSS inline styles    CSSCLASS=use classes
if (typeof ol_css == 'undefined') { var ol_css = CSSOFF; }

// Main background class (eqv of fgcolor)
// This is only used if CSS is set to use classes (ol_css = CSSCLASS)
if (typeof ol_fgclass == 'undefined') { var ol_fgclass = ""; }

// Frame background class (eqv of bgcolor)
// This is only used if CSS is set to use classes (ol_css = CSSCLASS)
if (typeof ol_bgclass == 'undefined') { var ol_bgclass = ""; }

// Main font class
// This is only used if CSS is set to use classes (ol_css = CSSCLASS)
if (typeof ol_textfontclass == 'undefined') { var ol_textfontclass = ""; }

// Caption font class
// This is only used if CSS is set to use classes (ol_css = CSSCLASS)
if (typeof ol_captionfontclass == 'undefined') { var ol_captionfontclass = ""; }

// Close font class
// This is only used if CSS is set to use classes (ol_css = CSSCLASS)
if (typeof ol_closefontclass == 'undefined') { var ol_closefontclass = ""; }

// Unit to be used for the text padding above
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
// Options include "px", "%", "in", "cm" and more
if (typeof ol_padunit == 'undefined') { var ol_padunit = "px";}

// Unit to be used for height of popup
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
// Options include "px", "%", "in", "cm" and more
if (typeof ol_heightunit == 'undefined') { var ol_heightunit = "px";}

// Unit to be used for width of popup
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
// Options include "px", "%", "in", "cm" and more
if (typeof ol_widthunit == 'undefined') { var ol_widthunit = "px";}

// Font size unit for the main text
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_textsizeunit == 'undefined') { var ol_textsizeunit = "px";}

// Decoration of the main text ("none", "underline", "line-through" or "blink")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_textdecoration == 'undefined') { var ol_textdecoration = "none";}

// Font style of the main text ("normal" or "italic")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_textstyle == 'undefined') { var ol_textstyle = "normal";}

// Font weight of the main text ("normal", "bold", "bolder", "lighter", ect.)
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_textweight == 'undefined') { var ol_textweight = "normal";}

// Font size unit for the caption
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_captionsizeunit == 'undefined') { var ol_captionsizeunit = "px";}

// Decoration of the caption ("none", "underline", "line-through" or "blink")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_captiondecoration == 'undefined') { var ol_captiondecoration = "none";}

// Font style of the caption ("normal" or "italic")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_captionstyle == 'undefined') { var ol_captionstyle = "normal";}

// Font weight of the caption ("normal", "bold", "bolder", "lighter", ect.)
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_captionweight == 'undefined') { var ol_captionweight = "bold";}

// Font size unit for the close text
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_closesizeunit == 'undefined') { var ol_closesizeunit = "px";}

// Decoration of the close text ("none", "underline", "line-through" or "blink")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_closedecoration == 'undefined') { var ol_closedecoration = "none";}

// Font style of the close text ("normal" or "italic")
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_closestyle == 'undefined') { var ol_closestyle = "normal";}

// Font weight of the close text ("normal", "bold", "bolder", "lighter", ect.)
// Only used if CSS inline styles are being used (ol_css = CSSSTYLE)
if (typeof ol_closeweight == 'undefined') { var ol_closeweight = "normal";}



////////////////////////////////////////////////////////////////////////////////////
// ARRAY CONFIGURATION
// You don't have to change anything here if you don't want to. The following
// arrays can be filled with text and html if you don't wish to pass it from
// your html page.
////////////////////////////////////////////////////////////////////////////////////

// Array with texts.
if (typeof ol_texts == 'undefined') { var ol_texts = new Array("Text 0", "Text 1"); }

// Array with captions.
if (typeof ol_caps == 'undefined') { var ol_caps = new Array("Caption 0", "Caption 1"); }


////////////////////////////////////////////////////////////////////////////////////
// END CONFIGURATION
// Don't change anything below this line, all configuration is above.
////////////////////////////////////////////////////////////////////////////////////







////////////////////////////////////////////////////////////////////////////////////
// INIT
////////////////////////////////////////////////////////////////////////////////////

// Runtime variables init. Used for runtime only, don't change, not for config!
var o3_text = "";
var o3_cap = "";
var o3_sticky = 0;
var o3_background = "";
var o3_close = "Close";
var o3_hpos = RIGHT;
var o3_offsetx = 2;
var o3_offsety = 2;
var o3_fgcolor = "";
var o3_bgcolor = "";
var o3_textcolor = "";
var o3_capcolor = "";
var o3_closecolor = "";
var o3_width = 100;
var o3_border = 1;
var o3_status = "";
var o3_autostatus = 0;
var o3_height = -1;
var o3_snapx = 0;
var o3_snapy = 0;
var o3_fixx = -1;
var o3_fixy = -1;
var o3_fgbackground = "";
var o3_bgbackground = "";
var o3_padxl = 0;
var o3_padxr = 0;
var o3_padyt = 0;
var o3_padyb = 0;
var o3_fullhtml = 0;
var o3_vpos = BELOW;
var o3_aboveheight = 0;
var o3_capicon = "";
var o3_textfont = "Verdana,Arial,Helvetica";
var o3_captionfont = "Verdana,Arial,Helvetica";
var o3_closefont = "Verdana,Arial,Helvetica";
var o3_textsize = "1";
var o3_captionsize = "1";
var o3_closesize = "1";
var o3_frame = self;
var o3_timeout = 0;
var o3_timerid = 0;
var o3_allowmove = 0;
var o3_function = Function();
var o3_delay = 0;
var o3_delayid = 0;
var o3_hauto = 0;
var o3_vauto = 0;
var o3_closeclick = 0;

var o3_css = CSSOFF;
var o3_fgclass = "";
var o3_bgclass = "";
var o3_textfontclass = "";
var o3_captionfontclass = "";
var o3_closefontclass = "";
var o3_padunit = "px";
var o3_heightunit = "px";
var o3_widthunit = "px";
var o3_textsizeunit = "px";
var o3_textdecoration = "";
var o3_textstyle = "";
var o3_textweight = "";
var o3_captionsizeunit = "px";
var o3_captiondecoration = "";
var o3_captionstyle = "";
var o3_captionweight = "";
var o3_closesizeunit = "px";
var o3_closedecoration = "";
var o3_closestyle = "";
var o3_closeweight = "";



// Display state variables
var o3_x = 0;
var o3_y = 0;
var o3_allow = 0;
var o3_showingsticky = 0;
var o3_removecounter = 0;

// Our layer
var over = null;


// Decide browser version
var ns4 = (document.layers)? true:false;
var ns6 = (document.getElementById)? true:false;
var ie4 = (document.all)? true:false;
var ie5 = false;

// Microsoft Stupidity Check(tm).
if (ie4) {
	if ((navigator.userAgent.indexOf('MSIE 5') > 0) || (navigator.userAgent.indexOf('MSIE 6') > 0)) {
		ie5 = true;
	}
	if (ns6) {
		ns6 = false;
	}
}


// Capture events, alt. diffuses the overlib function.
if ( (ns4) || (ie4) || (ns6)) {
	document.onmousemove = mouseMove
	if (ns4) document.captureEvents(Event.MOUSEMOVE)
} else {
	overlib = no_overlib;
	nd = no_overlib;
	ver3fix = true;
}


// Fake function for 3.0 users.
function no_overlib() {
	return ver3fix;
}



////////////////////////////////////////////////////////////////////////////////////
// PUBLIC FUNCTIONS
////////////////////////////////////////////////////////////////////////////////////


// overlib(arg0, ..., argN)
// Loads parameters into global runtime variables.
function overlib() {
	
	// Load defaults to runtime.
	o3_text = ol_text;
	o3_cap = ol_cap;
	o3_sticky = ol_sticky;
	o3_background = ol_background;
	o3_close = ol_close;
	o3_hpos = ol_hpos;
	o3_offsetx = ol_offsetx;
	o3_offsety = ol_offsety;
	o3_fgcolor = ol_fgcolor;
	o3_bgcolor = ol_bgcolor;
	o3_textcolor = ol_textcolor;
	o3_capcolor = ol_capcolor;
	o3_closecolor = ol_closecolor;
	o3_width = ol_width;
	o3_border = ol_border;
	o3_status = ol_status;
	o3_autostatus = ol_autostatus;
	o3_height = ol_height;
	o3_snapx = ol_snapx;
	o3_snapy = ol_snapy;
	o3_fixx = ol_fixx;
	o3_fixy = ol_fixy;
	o3_fgbackground = ol_fgbackground;
	o3_bgbackground = ol_bgbackground;
	o3_padxl = ol_padxl;
	o3_padxr = ol_padxr;
	o3_padyt = ol_padyt;
	o3_padyb = ol_padyb;
	o3_fullhtml = ol_fullhtml;
	o3_vpos = ol_vpos;
	o3_aboveheight = ol_aboveheight;
	o3_capicon = ol_capicon;
	o3_textfont = ol_textfont;
	o3_captionfont = ol_captionfont;
	o3_closefont = ol_closefont;
	o3_textsize = ol_textsize;
	o3_captionsize = ol_captionsize;
	o3_closesize = ol_closesize;
	o3_timeout = ol_timeout;
	o3_function = ol_function;
	o3_delay = ol_delay;
	o3_hauto = ol_hauto;
	o3_vauto = ol_vauto;
	o3_closeclick = ol_closeclick;
	
	o3_css = ol_css;
	o3_fgclass = ol_fgclass;
	o3_bgclass = ol_bgclass;
	o3_textfontclass = ol_textfontclass;
	o3_captionfontclass = ol_captionfontclass;
	o3_closefontclass = ol_closefontclass;
	o3_padunit = ol_padunit;
	o3_heightunit = ol_heightunit;
	o3_widthunit = ol_widthunit;
	o3_textsizeunit = ol_textsizeunit;
	o3_textdecoration = ol_textdecoration;
	o3_textstyle = ol_textstyle;
	o3_textweight = ol_textweight;
	o3_captionsizeunit = ol_captionsizeunit;
	o3_captiondecoration = ol_captiondecoration;
	o3_captionstyle = ol_captionstyle;
	o3_captionweight = ol_captionweight;
	o3_closesizeunit = ol_closesizeunit;
	o3_closedecoration = ol_closedecoration;
	o3_closestyle = ol_closestyle;
	o3_closeweight = ol_closeweight;
	

	// Special for frame support, over must be reset...
	if ( (ns4) || (ie4) || (ns6) ) {
		o3_frame = ol_frame;
		if (ns4) over = o3_frame.document.overDiv
		if (ie4) over = o3_frame.overDiv.style
		if (ns6) over = o3_frame.document.getElementById("overDiv");
	}
	
	
	// What the next argument is expected to be.
	var parsemode = -1;
	
	var ar = arguments;

	for (i = 0; i < ar.length; i++) {

		if (parsemode < 0) {
			// Arg is maintext, unless INARRAY
			if (ar[i] == INARRAY) {
				o3_text = ol_texts[ar[++i]];
			} else {
				o3_text = ar[i];
			}

			parsemode = 0;
		} else {
			// Note: NS4 doesn't like switch cases with vars.
			if (ar[i] == INARRAY) { o3_text = ol_texts[ar[++i]]; continue; }
			if (ar[i] == CAPARRAY) { o3_cap = ol_caps[ar[++i]]; continue; }
			if (ar[i] == STICKY) { o3_sticky = 1; continue; }
			if (ar[i] == BACKGROUND) { o3_background = ar[++i]; continue; }
			if (ar[i] == NOCLOSE) { o3_close = ""; continue; }
			if (ar[i] == CAPTION) { o3_cap = ar[++i]; continue; }
			if (ar[i] == CENTER || ar[i] == LEFT || ar[i] == RIGHT) { o3_hpos = ar[i]; continue; }
			if (ar[i] == OFFSETX) { o3_offsetx = ar[++i]; continue; }
			if (ar[i] == OFFSETY) { o3_offsety = ar[++i]; continue; }
			if (ar[i] == FGCOLOR) { o3_fgcolor = ar[++i]; continue; }
			if (ar[i] == BGCOLOR) { o3_bgcolor = ar[++i]; continue; }
			if (ar[i] == TEXTCOLOR) { o3_textcolor = ar[++i]; continue; }
			if (ar[i] == CAPCOLOR) { o3_capcolor = ar[++i]; continue; }
			if (ar[i] == CLOSECOLOR) { o3_closecolor = ar[++i]; continue; }
			if (ar[i] == WIDTH) { o3_width = ar[++i]; continue; }
			if (ar[i] == BORDER) { o3_border = ar[++i]; continue; }
			if (ar[i] == STATUS) { o3_status = ar[++i]; continue; }
			if (ar[i] == AUTOSTATUS) { o3_autostatus = 1; continue; }
			if (ar[i] == AUTOSTATUSCAP) { o3_autostatus = 2; continue; }
			if (ar[i] == HEIGHT) { o3_height = ar[++i]; o3_aboveheight = ar[i]; continue; } // Same param again.
			if (ar[i] == CLOSETEXT) { o3_close = ar[++i]; continue; }
			if (ar[i] == SNAPX) { o3_snapx = ar[++i]; continue; }
			if (ar[i] == SNAPY) { o3_snapy = ar[++i]; continue; }
			if (ar[i] == FIXX) { o3_fixx = ar[++i]; continue; }
			if (ar[i] == FIXY) { o3_fixy = ar[++i]; continue; }
			if (ar[i] == FGBACKGROUND) { o3_fgbackground = ar[++i]; continue; }
			if (ar[i] == BGBACKGROUND) { o3_bgbackground = ar[++i]; continue; }
			if (ar[i] == PADX) { o3_padxl = ar[++i]; o3_padxr = ar[++i]; continue; }
			if (ar[i] == PADY) { o3_padyt = ar[++i]; o3_padyb = ar[++i]; continue; }
			if (ar[i] == FULLHTML) { o3_fullhtml = 1; continue; }
			if (ar[i] == BELOW || ar[i] == ABOVE) { o3_vpos = ar[i]; continue; }
			if (ar[i] == CAPICON) { o3_capicon = ar[++i]; continue; }
			if (ar[i] == TEXTFONT) { o3_textfont = ar[++i]; continue; }
			if (ar[i] == CAPTIONFONT) { o3_captionfont = ar[++i]; continue; }
			if (ar[i] == CLOSEFONT) { o3_closefont = ar[++i]; continue; }
			if (ar[i] == TEXTSIZE) { o3_textsize = ar[++i]; continue; }
			if (ar[i] == CAPTIONSIZE) { o3_captionsize = ar[++i]; continue; }
			if (ar[i] == CLOSESIZE) { o3_closesize = ar[++i]; continue; }
			if (ar[i] == FRAME) { opt_FRAME(ar[++i]); continue; }
			if (ar[i] == TIMEOUT) { o3_timeout = ar[++i]; continue; }
			if (ar[i] == FUNCTION) { opt_FUNCTION(ar[++i]); continue; }
			if (ar[i] == DELAY) { o3_delay = ar[++i]; continue; }
			if (ar[i] == HAUTO) { o3_hauto = (o3_hauto == 0) ? 1 : 0; continue; }
			if (ar[i] == VAUTO) { o3_vauto = (o3_vauto == 0) ? 1 : 0; continue; }
			if (ar[i] == CLOSECLICK) { o3_closeclick = (o3_closeclick == 0) ? 1 : 0; continue; }
			if (ar[i] == CSSOFF) { o3_css = ar[i]; continue; }
			if (ar[i] == CSSSTYLE) { o3_css = ar[i]; continue; }
			if (ar[i] == CSSCLASS) { o3_css = ar[i]; continue; }
			if (ar[i] == FGCLASS) { o3_fgclass = ar[++i]; continue; }
			if (ar[i] == BGCLASS) { o3_bgclass = ar[++i]; continue; }
			if (ar[i] == TEXTFONTCLASS) { o3_textfontclass = ar[++i]; continue; }
			if (ar[i] == CAPTIONFONTCLASS) { o3_captionfontclass = ar[++i]; continue; }
			if (ar[i] == CLOSEFONTCLASS) { o3_closefontclass = ar[++i]; continue; }
			if (ar[i] == PADUNIT) { o3_padunit = ar[++i]; continue; }
			if (ar[i] == HEIGHTUNIT) { o3_heightunit = ar[++i]; continue; }
			if (ar[i] == WIDTHUNIT) { o3_widthunit = ar[++i]; continue; }
			if (ar[i] == TEXTSIZEUNIT) { o3_textsizeunit = ar[++i]; continue; }
			if (ar[i] == TEXTDECORATION) { o3_textdecoration = ar[++i]; continue; }
			if (ar[i] == TEXTSTYLE) { o3_textstyle = ar[++i]; continue; }
			if (ar[i] == TEXTWEIGHT) { o3_textweight = ar[++i]; continue; }
			if (ar[i] == CAPTIONSIZEUNIT) { o3_captionsizeunit = ar[++i]; continue; }
			if (ar[i] == CAPTIONDECORATION) { o3_captiondecoration = ar[++i]; continue; }
			if (ar[i] == CAPTIONSTYLE) { o3_captionstyle = ar[++i]; continue; }
			if (ar[i] == CAPTIONWEIGHT) { o3_captionweight = ar[++i]; continue; }
			if (ar[i] == CLOSESIZEUNIT) { o3_closesizeunit = ar[++i]; continue; }
			if (ar[i] == CLOSEDECORATION) { o3_closedecoration = ar[++i]; continue; }
			if (ar[i] == CLOSESTYLE) { o3_closestyle = ar[++i]; continue; }
			if (ar[i] == CLOSEWEIGHT) { o3_closeweight = ar[++i]; continue; }
		}
	}

	if (o3_delay == 0) {
		return overlib350();
	} else {
		o3_delayid = setTimeout("overlib350()", o3_delay);

		if (o3_sticky) {
			return false;
		} else {
			return true;
		}
	}
}



// Clears popups if appropriate
function nd() {
	if ( o3_removecounter >= 1 ) { o3_showingsticky = 0 };
	if ( (ns4) || (ie4) || (ns6) ) {
		if ( o3_showingsticky == 0 ) {
			o3_allowmove = 0;
			if (over != null) hideObject(over);
		} else {
			o3_removecounter++;
		}
	}
	
	return true;
}







////////////////////////////////////////////////////////////////////////////////////
// OVERLIB 3.50 FUNCTION
////////////////////////////////////////////////////////////////////////////////////


// This function decides what it is we want to display and how we want it done.
function overlib350() {

	// Make layer content
	var layerhtml;

	if (o3_background != "" || o3_fullhtml) {
		// Use background instead of box.
		layerhtml = ol_content_background(o3_text, o3_background, o3_fullhtml);
	} else {
		// They want a popup box.

		// Prepare popup background
		if (o3_fgbackground != "" && o3_css == CSSOFF) {
			o3_fgbackground = "BACKGROUND=\""+o3_fgbackground+"\"";
		}
		if (o3_bgbackground != "" && o3_css == CSSOFF) {
			o3_bgbackground = "BACKGROUND=\""+o3_bgbackground+"\"";
		}

		// Prepare popup colors
		if (o3_fgcolor != "" && o3_css == CSSOFF) {
			o3_fgcolor = "BGCOLOR=\""+o3_fgcolor+"\"";
		}
		if (o3_bgcolor != "" && o3_css == CSSOFF) {
			o3_bgcolor = "BGCOLOR=\""+o3_bgcolor+"\"";
		}

		// Prepare popup height
		if (o3_height > 0 && o3_css == CSSOFF) {
			o3_height = "HEIGHT=" + o3_height;
		} else {
			o3_height = "";
		}

		// Decide which kinda box.
		if (o3_cap == "") {
			// Plain
			layerhtml = ol_content_simple(o3_text);
		} else {
			// With caption
			if (o3_sticky) {
				// Show close text
				layerhtml = ol_content_caption(o3_text, o3_cap, o3_close);
			} else {
				// No close text
				layerhtml = ol_content_caption(o3_text, o3_cap, "");
			}
		}
	}
	
	// We want it to stick!
	if (o3_sticky) {
		o3_showingsticky = 1;
		o3_removecounter = 0;
	}
	
	// Write layer
	layerWrite(layerhtml);
	
	// Prepare status bar
	if (o3_autostatus > 0) {
		o3_status = o3_text;
		if (o3_autostatus > 1) {
			o3_status = o3_cap;
		}
	}

	// When placing the layer the first time, even stickies may be moved.
	o3_allowmove = 0;

	// Initiate a timer for timeout
	if (o3_timeout > 0) {          
		if (o3_timerid > 0) clearTimeout(o3_timerid);
		o3_timerid = setTimeout("cClick()", o3_timeout);
	}

	// Show layer
	disp(o3_status);

	// Stickies should stay where they are.	
	if (o3_sticky) {
		o3_allowmove = 0;
		return false;
	} else {
		return true;
	}
}



////////////////////////////////////////////////////////////////////////////////////
// LAYER GENERATION FUNCTIONS
////////////////////////////////////////////////////////////////////////////////////

// Makes simple table without caption
function ol_content_simple(text) {
	if (o3_css == CSSCLASS) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 class=\""+o3_bgclass+"\"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 class=\""+o3_fgclass+"\"><TR><TD VALIGN=TOP><FONT class=\""+o3_textfontclass+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";
	if (o3_css == CSSSTYLE) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 style=\"background-color: "+o3_bgcolor+"; height: "+o3_height+o3_heightunit+";\"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 style=\"color: "+o3_fgcolor+"; background-color: "+o3_fgcolor+"; height: "+o3_height+o3_heightunit+";\"><TR><TD VALIGN=TOP><FONT style=\"font-family: "+o3_textfont+"; color: "+o3_textcolor+"; font-size: "+o3_textsize+o3_textsizeunit+"; text-decoration: "+o3_textdecoration+"; font-weight: "+o3_textweight+"; font-style:"+o3_textstyle+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";
	if (o3_css == CSSOFF) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 "+o3_bgcolor+" "+o3_height+"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 "+o3_fgcolor+" "+o3_fgbackground+" "+o3_height+"><TR><TD VALIGN=TOP><FONT FACE=\""+o3_textfont+"\" COLOR=\""+o3_textcolor+"\" SIZE=\""+o3_textsize+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";

	set_background("");
	return txt;
}




// Makes table with caption and optional close link
function ol_content_caption(text, title, close) {
	closing = "";
	closeevent = "onMouseOver";

	if (o3_closeclick == 1) closeevent = "onClick";
	if (o3_capicon != "") o3_capicon = "<IMG SRC=\""+o3_capicon+"\"> ";

	if (close != "") {
		if (o3_css == CSSCLASS) closing = "<TD ALIGN=RIGHT><A HREF=\"/\" "+closeevent+"=\"return cClick();\" class=\""+o3_closefontclass+"\">"+close+"</A></TD>";
		if (o3_css == CSSSTYLE) closing = "<TD ALIGN=RIGHT><A HREF=\"/\" "+closeevent+"=\"return cClick();\" style=\"color: "+o3_closecolor+"; font-family: "+o3_closefont+"; font-size: "+o3_closesize+o3_closesizeunit+"; text-decoration: "+o3_closedecoration+"; font-weight: "+o3_closeweight+"; font-style:"+o3_closestyle+";\">"+close+"</A></TD>";
		if (o3_css == CSSOFF) closing = "<TD ALIGN=RIGHT><A HREF=\"/\" "+closeevent+"=\"return cClick();\"><FONT COLOR=\""+o3_closecolor+"\" FACE=\""+o3_closefont+"\" SIZE=\""+o3_closesize+"\">"+close+"</FONT></A></TD>";
	}

	if (o3_css == CSSCLASS) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 class=\""+o3_bgclass+"\"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=0 CELLSPACING=0><TR><TD><FONT class=\""+o3_captionfontclass+"\">"+o3_capicon+title+"</FONT></TD>"+closing+"</TR></TABLE><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 class=\""+o3_fgclass+"\"><TR><TD VALIGN=TOP><FONT class=\""+o3_textfontclass+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";
	if (o3_css == CSSSTYLE) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 style=\"background-color: "+o3_bgcolor+"; background-image: url("+o3_bgbackground+"); height: "+o3_height+o3_heightunit+";\"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=0 CELLSPACING=0><TR><TD><FONT style=\"font-family: "+o3_captionfont+"; color: "+o3_capcolor+"; font-size: "+o3_captionsize+o3_captionsizeunit+"; font-weight: "+o3_captionweight+"; font-style: "+o3_captionstyle+";\">"+o3_capicon+title+"</FONT></TD>"+closing+"</TR></TABLE><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 style=\"color: "+o3_fgcolor+"; background-color: "+o3_fgcolor+"; height: "+o3_height+o3_heightunit+";\"><TR><TD VALIGN=TOP><FONT style=\"font-family: "+o3_textfont+"; color: "+o3_textcolor+"; font-size: "+o3_textsize+o3_textsizeunit+"; text-decoration: "+o3_textdecoration+"; font-weight: "+o3_textweight+"; font-style:"+o3_textstyle+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";
	if (o3_css == CSSOFF) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING="+o3_border+" CELLSPACING=0 "+o3_bgcolor+" "+o3_bgbackground+" "+o3_height+"><TR><TD><TABLE WIDTH=100% BORDER=0 CELLPADDING=0 CELLSPACING=0><TR><TD><B><FONT COLOR=\""+o3_capcolor+"\" FACE=\""+o3_captionfont+"\" SIZE=\""+o3_captionsize+"\">"+o3_capicon+title+"</FONT></B></TD>"+closing+"</TR></TABLE><TABLE WIDTH=100% BORDER=0 CELLPADDING=2 CELLSPACING=0 "+o3_fgcolor+" "+o3_fgbackground+" "+o3_height+"><TR><TD VALIGN=TOP><FONT COLOR=\""+o3_textcolor+"\" FACE=\""+o3_textfont+"\" SIZE=\""+o3_textsize+"\">"+text+"</FONT></TD></TR></TABLE></TD></TR></TABLE>";

	set_background("");
	return txt;
}

// Sets the background picture, padding and lots more. :)
function ol_content_background(text, picture, hasfullhtml) {
	if (hasfullhtml) {
		txt = text;
	} else {
		if (o3_css == CSSCLASS) txt = "<TABLE WIDTH="+o3_width+o3_widthunit+" BORDER=0 CELLPADDING=0 CELLSPACING=0 HEIGHT="+o3_height+o3_heightunit+"><TR><TD COLSPAN=3 HEIGHT="+o3_padyt+o3_padunit+"></TD></TR><TR><TD WIDTH="+o3_padxl+o3_padunit+"></TD><TD VALIGN=TOP WIDTH="+(o3_width-o3_padxl-o3_padxr)+o3_padunit+"><FONT class=\""+o3_textfontclass+"\">"+text+"</FONT></TD><TD WIDTH="+o3_padxr+o3_padunit+"></TD></TR><TR><TD COLSPAN=3 HEIGHT="+o3_padyb+o3_padunit+"></TD></TR></TABLE>";
		if (o3_css == CSSSTYLE) txt = "<TABLE WIDTH="+o3_width+o3_widthunit+" BORDER=0 CELLPADDING=0 CELLSPACING=0 HEIGHT="+o3_height+o3_heightunit+"><TR><TD COLSPAN=3 HEIGHT="+o3_padyt+o3_padunit+"></TD></TR><TR><TD WIDTH="+o3_padxl+o3_padunit+"></TD><TD VALIGN=TOP WIDTH="+(o3_width-o3_padxl-o3_padxr)+o3_padunit+"><FONT style=\"font-family: "+o3_textfont+"; color: "+o3_textcolor+"; font-size: "+o3_textsize+o3_textsizeunit+";\">"+text+"</FONT></TD><TD WIDTH="+o3_padxr+o3_padunit+"></TD></TR><TR><TD COLSPAN=3 HEIGHT="+o3_padyb+o3_padunit+"></TD></TR></TABLE>";
		if (o3_css == CSSOFF) txt = "<TABLE WIDTH="+o3_width+" BORDER=0 CELLPADDING=0 CELLSPACING=0 HEIGHT="+o3_height+"><TR><TD COLSPAN=3 HEIGHT="+o3_padyt+"></TD></TR><TR><TD WIDTH="+o3_padxl+"></TD><TD VALIGN=TOP WIDTH="+(o3_width-o3_padxl-o3_padxr)+"><FONT FACE=\""+o3_textfont+"\" COLOR=\""+o3_textcolor+"\" SIZE=\""+o3_textsize+"\">"+text+"</FONT></TD><TD WIDTH="+o3_padxr+"></TD></TR><TR><TD COLSPAN=3 HEIGHT="+o3_padyb+"></TD></TR></TABLE>";
	}
	set_background(picture);
	return txt;
}

// Loads a picture into the div.
function set_background(pic) {
	if (pic == "") {
		if (ie4) over.backgroundImage = "none";
		if (ns6) over.style.backgroundImage = "none";
	} else {
		if (ns4) {
			over.background.src = pic;
		} else if (ie4) {
			over.backgroundImage = "url("+pic+")";
		} else if (ns6) {
			over.style.backgroundImage = "url("+pic+")";
		}
	}
}



////////////////////////////////////////////////////////////////////////////////////
// HANDLING FUNCTIONS
////////////////////////////////////////////////////////////////////////////////////


// Displays the popup
function disp(statustext) {
	if ( (ns4) || (ie4) || (ns6) ) {
		if (o3_allowmove == 0) 	{
			placeLayer();
			showObject(over);
			o3_allowmove = 1;
		}
	}

	if (statustext != "") {
		self.status = statustext;
	}
}

// Decides where we want the popup.
function placeLayer() {
	var placeX, placeY;
	
	// HORIZONTAL PLACEMENT
	if (o3_fixx > -1) {
		// Fixed position
		placeX = o3_fixx;
	} else {
		winoffset = (ie4) ? o3_frame.document.body.scrollLeft : o3_frame.pageXOffset;
		if (ie4) iwidth = o3_frame.document.body.clientWidth;
		if (ns4) iwidth = o3_frame.innerWidth; // was screwed in mozilla, fixed now?
		if (ns6) iwidth = o3_frame.outerWidth;
		
		// If HAUTO, decide what to use.
		if (o3_hauto == 1) {
			if ( (o3_x - winoffset) > ((eval(iwidth)) / 2)) {
				o3_hpos = LEFT;
			} else {
				o3_hpos = RIGHT;
			}
		}
		
		// From mouse
		if (o3_hpos == CENTER) { // Center
			placeX = o3_x+o3_offsetx-(o3_width/2);
		}
		if (o3_hpos == RIGHT) { // Right
			placeX = o3_x+o3_offsetx;
			if ( (eval(placeX) + eval(o3_width)) > (winoffset + iwidth) ) {
				placeX = iwidth + winoffset - o3_width;
				if (placeX < 0) placeX = 0;
			}
		}
		if (o3_hpos == LEFT) { // Left
			placeX = o3_x-o3_offsetx-o3_width;
			if (placeX < winoffset) placeX = winoffset;
		}
	
		// Snapping!
		if (o3_snapx > 1) {
			var snapping = placeX % o3_snapx;
			if (o3_hpos == LEFT) {
				placeX = placeX - (o3_snapx + snapping);
			} else {
				// CENTER and RIGHT
				placeX = placeX + (o3_snapx - snapping);
			}
			if (placeX < winoffset) placeX = winoffset;
		}
	}

	
	
	// VERTICAL PLACEMENT
	if (o3_fixy > -1) {
		// Fixed position
		placeY = o3_fixy;
	} else {
		scrolloffset = (ie4) ? o3_frame.document.body.scrollTop : o3_frame.pageYOffset;

		// If VAUTO, decide what to use.
		if (o3_vauto == 1) {
			if (ie4) iheight = o3_frame.document.body.clientHeight;
			if (ns4) iheight = o3_frame.innerHeight;
			if (ns6) iheight = o3_frame.outerHeight;

			iheight = (eval(iheight)) / 2;
			if ( (o3_y - scrolloffset) > iheight) {
				o3_vpos = ABOVE;
			} else {
				o3_vpos = BELOW;
			}
		}


		// From mouse
		if (o3_vpos == ABOVE) {
			if (o3_aboveheight == 0) {
				var divref = (ie4) ? o3_frame.document.all['overDiv'] : over;
				o3_aboveheight = (ns4) ? divref.clip.height : divref.offsetHeight;
			}

			placeY = o3_y - (o3_aboveheight + o3_offsety);
			if (placeY < scrolloffset) placeY = scrolloffset;
		} else {
			// BELOW
			placeY = o3_y + o3_offsety;
		}

		// Snapping!
		if (o3_snapy > 1) {
			var snapping = placeY % o3_snapy;
			
			if (o3_aboveheight > 0 && o3_vpos == ABOVE) {
				placeY = placeY - (o3_snapy + snapping);
			} else {
				placeY = placeY + (o3_snapy - snapping);
			}
			
			if (placeY < scrolloffset) placeY = scrolloffset;
		}
	}


	// Actually move the object.	
	repositionTo(over, placeX, placeY);
}


// Moves the layer
function mouseMove(e) {
	if ( (ns4) || (ns6) ) {o3_x=e.pageX; o3_y=e.pageY;}
	if (ie4) {o3_x=event.x; o3_y=event.y;}
	if (ie5) {o3_x=event.x+o3_frame.document.body.scrollLeft; o3_y=event.y+o3_frame.document.body.scrollTop;}
	
	if (o3_allowmove == 1) {
		placeLayer();
	}
}

// The Close onMouseOver function for stickies
function cClick() {
	hideObject(over);
	o3_showingsticky = 0;
	
	return false;
}


// Makes sure target frame has overLIB
function compatibleframe(frameid) {        
	if (ns4) {
		if (typeof frameid.document.overDiv =='undefined') return false;
	} else if (ie4) {
		if (typeof frameid.document.all["overDiv"] =='undefined') return false;
	} else if (ns6) {
		if (frameid.document.getElementById('overDiv') == null) return false;
	}

	return true;
}



////////////////////////////////////////////////////////////////////////////////////
// LAYER FUNCTIONS
////////////////////////////////////////////////////////////////////////////////////


// Writes to a layer
function layerWrite(txt) {
	txt += "\n";
	
        if (ns4) {
                var lyr = o3_frame.document.overDiv.document

                lyr.write(txt)
                lyr.close()
        } else if (ie4) {
		o3_frame.document.all["overDiv"].innerHTML = txt
	} else if (ns6) {
		range = o3_frame.document.createRange();
		range.setStartBefore(over);
		domfrag = range.createContextualFragment(txt);
		while (over.hasChildNodes()) {
			over.removeChild(over.lastChild);
		}
		over.appendChild(domfrag);
	}
}

// Make an object visible
function showObject(obj) {
        if (ns4) obj.visibility = "show";
        else if (ie4) obj.visibility = "visible";
	else if (ns6) obj.style.visibility = "visible";
}

// Hides an object
function hideObject(obj) {
        if (ns4) obj.visibility = "hide";
        else if (ie4) obj.visibility = "hidden";
	else if (ns6) obj.style.visibility = "hidden";
        
	if (o3_timerid > 0) clearTimeout(o3_timerid);
	if (o3_delayid > 0) clearTimeout(o3_delayid);
	o3_timerid = 0;
	o3_delayid = 0;
        self.status = "";
}

// Move a layer
function repositionTo(obj,xL,yL) {
	if ( (ns4) || (ie4) ) {
	        obj.left = xL;
	        obj.top = yL;
	} else if (ns6) {
		obj.style.left = xL + "px";
		obj.style.top = yL+ "px";
	}
}





////////////////////////////////////////////////////////////////////////////////////
// PARSER FUNCTIONS
////////////////////////////////////////////////////////////////////////////////////


// Defines which frame we should point to.
function opt_FRAME(frm) {
        o3_frame = compatibleframe(frm) ? frm : ol_frame;

	if ( (ns4) || (ie4 || (ns6)) ) {
		if (ns4) over = o3_frame.document.overDiv;
		if (ie4) over = o3_frame.overDiv.style;
		if (ns6) over = o3_frame.document.getElementById("overDiv");
	}

	return 0;
}

// Calls an external function
function opt_FUNCTION(callme) {
	o3_text = callme()
	return 0;
}




//end (For internal purposes.)
////////////////////////////////////////////////////////////////////////////////////
// OVERLIB 2 COMPATABILITY FUNCTIONS
// If you aren't upgrading you can remove the below section.
////////////////////////////////////////////////////////////////////////////////////

// Converts old 0=left, 1=right and 2=center into constants.
function vpos_convert(d) {
	if (d == 0) {
		d = LEFT;
	} else {
		if (d == 1) {
			d = RIGHT;
		} else {
			d = CENTER;
		}
	}
	
	return d;
}

// Simple popup
function dts(d,text) {
	o3_hpos = vpos_convert(d);
	overlib(text, o3_hpos, CAPTION, "");
}

// Caption popup
function dtc(d,text, title) {
	o3_hpos = vpos_convert(d);
	overlib(text, CAPTION, title, o3_hpos);
}

// Sticky
function stc(d,text, title) {
	o3_hpos = vpos_convert(d);
	overlib(text, CAPTION, title, o3_hpos, STICKY);
}

// Simple popup right
function drs(text) {
	dts(1,text);
}

// Caption popup right
function drc(text, title) {
	dtc(1,text,title);
}

// Sticky caption right
function src(text,title) {
	stc(1,text,title);
}

// Simple popup left
function dls(text) {
	dts(0,text);
}

// Caption popup left
function dlc(text, title) {
	dtc(0,text,title);
}

// Sticky caption left
function slc(text,title) {
	stc(0,text,title);
}

// Simple popup center
function dcs(text) {
	dts(2,text);
}

// Caption popup center
function dcc(text, title) {
	dtc(2,text,title);
}

// Sticky caption center
function scc(text,title) {
	stc(2,text,title);
}

